Train the technique.

Synthetic tissue that behaves the same in the fortieth cohort as it did in the first, with the measured properties published so you can prove it.

6 formulations
A continuous compliance range, baseline through ultra-soft
3 to 10 MHz
Acoustic response characterized across clinical probe frequencies
8 to 10 remelts
Melt it down and remold it, and it behaves the same afterward
Certificate of Analysis
Ships with every unit, no exceptions

The material is the variable most programs never control.

Animal tissue varies by specimen. Organic gelatin begins degrading within days. When the practice medium changes between sessions, so does the skill your learners walk away with, and nobody can tell you by how much.

Humimic SimuGel™ is engineered so that variable holds still. Properties are reported as population means with measured variance across validated production batches, and every unit ships with a Certificate of Analysis. Full mechanical and acoustic data is published on the Device Testing page.

Against silicone simulants
What the program needsSimuGelTypical silicone simulant
To see it on screen Characterized at 3, 5 and 10 MHz, with impedance inside the human soft-tissue band, so the needle tip and the target both resolve. Many silicone simulants image poorly on ultrasound, which turns a guided procedure into a guess at where the tip went.
To know what it does Full mechanical and acoustic properties published. A Certificate of Analysis ships with every unit. Proprietary formulations. Property data is not released, so the behavior you are training against is undisclosed.
To survive the calendar Self-healing between insertions, and it can be remelted 8 to 10 times and still behave the same. A cured elastomer cannot be melted down. Once a model is worn, it is replaced rather than restored.
To fit the procedure Six calibrated formulations across 0.11 to 0.58 MPa, available as raw material, built phantoms, or custom geometry. A finished model ships at one fixed stiffness. Different procedure, different purchase.

A material whose behavior is not documented is a material you cannot validate against, or standardize a curriculum on.

Vascular and needle access

Learners feel the same resistance on the first attempt and the hundredth, so what they build is technique rather than an adaptation to whatever the model is doing today.

  • Choose the resistance the procedure calls forYoung's modulus spans 0.11 to 0.58 MPa across six calibrated formulations.
  • Self-healing between attemptsPuncture tracks close, so a single unit carries a full cohort without accumulating damage that changes the feel.
  • No cold chain, no biohazardShelf-stable at room temperature. Synthetic composition, so there is no biological handling or disposal burden.
See the vascular access trainer

Ultrasound-guided procedures

Many silicone simulants image poorly on screen, which quietly turns an ultrasound lesson into a guessing exercise. SimuGel is characterized across the frequencies your probes actually run.

  • Real imaging, with the measurement behind itAcoustic impedance of 1.25 to 1.64 MRayl sits inside the human soft-tissue band of 1.3 to 1.7 MRayl.
  • Characterized at 3, 5 and 10 MHzThe range vascular and regional-anesthesia probes operate in.
  • Needle and anatomy both resolveSo the learner is reading the screen, not guessing at where the tip went.
See the ultrasound phantoms

HRT, BHRT and hormone pellet training

Most pellet certification still puts a provider on a live patient under a proctor for their first insertion. That is a lot of pressure on one attempt, and it limits how many repetitions a course can offer. SimuGel gives training programs a medium that behaves the same way every time, so trocar handling and placement depth are already familiar before anyone touches a patient.

  • The same trocar behavior every sessionAt every site, under every instructor, in every cohort.
  • Consistent from batch to batchProperties are reported as population means with measured variance across validated production batches.
  • Built for competency assessmentEvaluate handling, placement depth and procedural consistency under conditions that do not move between candidates.
  • Matched to the insertion siteMost pellet training programs run on SimuGel #3, and custom models can be built to the site and depth your curriculum teaches.
Discuss a hormone pellet training application

Engineered for external training and simulation. Not for clinical or in-body use.

Nerve block and pain management

The most common novice error in regional anesthesia is advancing the needle while the tip is not visualized. Targets are often only 3 to 5 mm across, and the difference between a perineural and an intraneural injection is the whole lesson. Drilling that habit takes a medium that resolves on screen every time.

  • Small targets stay legibleAcoustic impedance of 1.25 to 1.64 MRayl and characterization at 3, 5 and 10 MHz keep both the needle tip and the target readable on a high-frequency probe.
  • Hydrodissection behaves predictablyThe more compliant formulations accept simulated injectate cleanly, so trainees practice confirming tip position before delivery rather than after.
  • Match the tissue to the block depthSuperficial, truncal and lower-extremity blocks each sit at a different depth through different tissue. A compliance range of 0.11 to 0.58 MPa covers them rather than forcing one model to serve all three.
  • Nerve and vessel targets built to specSmaller nerves are identified by their relationship to nearby vessels, so custom models can carry both reference structures embedded in the same build.
See the task trainers

Engineered for external training and simulation. Not for clinical or in-body use.

Six formulations, matched to 22 target tissues.

Choose by the tissue the procedure works through, not by product number. The Reference Kit puts the full range side by side so your clinical lead can compare them in one sitting.

#0
Baseline
CartilageDense fibrousTendon
#1
Lower resistance
Skeletal muscleCardiac muscleLigament
#2
Medium-soft
BreastProstateCervix
#3
Soft
PancreasGlandularUterus
#4
Very soft
FatLiverKidney
#5
Ultra-soft
BrainNeonatalBlood clot
Baseline · 0.58 MPa Ultra-soft · 0.11 MPa

Targets shown are a representative selection from the full 22-tissue table.

Why programs stay.

Proven where it counts

In use across residency programs and clinical training labs.

Survives the calendar

Self-healing, and it can be melted down and remolded 8 to 10 times without changing how it behaves.

Documented, not asserted

A Certificate of Analysis ships with every unit, verifying performance against validated tolerances.

Made in the USA

Manufactured in Greenville, South Carolina, with next-business-day shipping on most orders.

Built to your anatomy, not around it.

Custom simulation models built from SimuGel synthetic tissue, engineered to your geometry and your protocol.

Discuss your application

From the journal.

What is a curvilinear transducer and how is it used?

Medical simulation
23 Dec 2025

Why use a curvilinear ultrasound probe for abdominal scans?

Medical simulation
16 Dec 2025

Tan dye in simulation, what it is and why it matters

Product knowledge
7 Oct 2025
Browse all articles